Share Email Print
cover

Journal of Biomedical Optics

Wavelength selection-based nonlinear calibration for transcutaneous blood glucose sensing using Raman spectroscopy
Author(s): Narahara Chari Dingari; Ishan Barman; Jeon Woong Kang; Chae-Ryon Kong; Ramachandra R. Dasari; Michael S. Feld
Format Member Price Non-Member Price
PDF $20.00 $25.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

While Raman spectroscopy provides a powerful tool for noninvasive and real time diagnostics of biological samples, its translation to the clinical setting has been impeded by the lack of robustness of spectroscopic calibration models and the size and cumbersome nature of conventional laboratory Raman systems. Linear multivariate calibration models employing full spectrum analysis are often misled by spurious correlations, such as system drift and covariations among constituents. In addition, such calibration schemes are prone to overfitting, especially in the presence of external interferences that may create nonlinearities in the spectra-concentration relationship. To address both of these issues we incorporate residue error plot-based wavelength selection and nonlinear support vector regression (SVR). Wavelength selection is used to eliminate uninformative regions of the spectrum, while SVR is used to model the curved effects such as those created by tissue turbidity and temperature fluctuations. Using glucose detection in tissue phantoms as a representative example, we show that even a substantial reduction in the number of wavelengths analyzed using SVR lead to calibration models of equivalent prediction accuracy as linear full spectrum analysis. Further, with clinical datasets obtained from human subject studies, we also demonstrate the prospective applicability of the selected wavelength subsets without sacrificing prediction accuracy, which has extensive implications for calibration maintenance and transfer. Additionally, such wavelength selection could substantially reduce the collection time of serial Raman acquisition systems. Given the reduced footprint of serial Raman systems in relation to conventional dispersive Raman spectrometers, we anticipate that the incorporation of wavelength selection in such hardware designs will enhance the possibility of miniaturized clinical systems for disease diagnosis in the near future.

Paper Details

Date Published: 1 August 2011
PDF: 11 pages
J. Biomed. Opt. 16(8) 087009 doi: 10.1117/1.3611006
Published in: Journal of Biomedical Optics Volume 16, Issue 8
Show Author Affiliations
Narahara Chari Dingari, Massachusetts Institute of Technology (United States)
Ishan Barman, Massachusetts Institute of Technology (United States)
Jeon Woong Kang, Massachusetts Institute of Technology (United States)
Chae-Ryon Kong, Massachusetts Institute of Technology (United States)
Ramachandra R. Dasari, Massachusetts Institute of Technology (United States)
Michael S. Feld, Massachusetts Institute of Technology (United States)


© SPIE. Terms of Use
Back to Top