Automated algorithm for breast tissue differentiation in optical coherence tomography
Format Member Price Non-Member Price
PDF $20.00 $25.00

Paper Abstract

An automated algorithm for differentiating breast tissue types based on optical coherence tomography (OCT) data is presented. Eight parameters are derived from the OCT reflectivity profiles and their means and covariance matrices are calculated for each tissue type from a training set (48 samples) selected based on histological examination. A quadratic discrimination score is then used to assess the samples from a validation set. The algorithm results for a set of 89 breast tissue samples were correlated with the histological findings, yielding specificity and sensitivity of 0.88. If further perfected to work in real time and yield even higher sensitivity and specificity, this algorithm would be a valuable tool for biopsy guidance and could significantly increase procedure reliability by reducing both the number of nondiagnostic aspirates and the number of false negatives.

Paper Details

Date Published: 1 May 2009
PDF: 9 pages
J. Biomed. Opt. 14(3) 034040 doi: 10.1117/1.3156821
Published in: Journal of Biomedical Optics Volume 14, Issue 3
Show Author Affiliations
Mircea Mujat, Physical Sciences Inc. (United States)
Robert Daniel Ferguson, Physical Sciences Inc. (United States)
Daniel X. Hammer, Physical Sciences Inc. (United States)
Christopher M. Gittins, Physical Sciences Inc. (United States)
Nicusor V. Iftimia, Physical Sciences Inc. (United States)